Calculate the Total Energy Use Intensity &
Thermal Energy Demand Intensity of Buildings or Homes

This tool helps you calculate the Total Energy Use Intensity (TEUI) & Thermal Energy Demand Intensity (TEDI) of a building or home.
Simply enter your information in the fields below then click the download button to generate a TEUI or TEDI Factsheet. Only for Ontario-based projects.
Press the tab key on your keyboard to jump to the next input field and enter values for your building or project. Default values exist to speed up the process.

TEUI Factsheet

Major Occupancy
Ontario Location
Compliance Standard
Occupants per Building
Building Size (GCA)
Project Reference
Operational Emissions per Building
MT CO2e/yr
Carbon
0.92
% National Average
Energy Consumption
43 GJ/year
20%
Total Electricity Use
kWh/yr
40945700 Btu/hr
Total Natural Gas Use
0 ekWh/yr
Total Oil Use
litres/yr
0 ekWh/yr
Total Energy Use Intensity (TEUI)
40.00 kWh/m²/yr
20%
CO2e Emissions
0.92 MT CO2e/yr
13%
Operational GHG Intensity
0.31 kg CO2e/m²/yr
1%
Embedded Carbon Emitted
MT
96%
Embedded Carbon Intensity
250 kg/m²
83%
Onsite Energy Production
0 kWh/yr
0%
Photovoltaics
kWh/yr
Geothermal
kWh/yr
Wind
kWh/yr
Offsite Renewable (REC's)
0 kWh/yr
0%
WWS Electricity
kWh/yr
Green Natural Gas
0 ekWh/yr
Annual Water Usage
litres/yr
5%
Indoor Air Quality
Good
Radon (annual avg.)
Bq/m³
33%
CO2 (annual avg.)
ppm
60%
TVOC (annual avg.)
ppm
67%
Rel. Humidity (annual avg.)
%
40%
Atmospheric Offsets
MT/yr CO2e
0%
% OBC Requirement
Building U-Value Avg.
0 W/m²•K
0%
Cooling Degree Days
Heating Degree Days
Coldest Days
ºC
Hottest Days
ºC
Thermostat Setpoint Heating
ºC
Thermostat Setpoint Cooling
ºC
Walls Below Grade (Rsi)
K•m²/W
108%
Walls Above Grade (Rsi)
K•m²/W
107%
Floor Exposed (Rsi)
K•m²/W
106%
Floor Slab - Heated (Rsi)
K•m²/W
102%
Window:Wall Ratio
0%
0%
Roof (Rsi)
K•m²/W
123%
Doors (U-value)
W/m²•K
178%
Windows (U-value)
W/m²•K
178%
ASHP Efficiency
HSPF
197%
DWHR Efficiency
%
100%
HRV/ERV Efficiency
%
109%
ACH (@50Pa)
ACH@50Pa
100%
ELA
150%
Energy Conservation Points Summary
Points
100%

TEDI Factsheet

Envelope Components
Areas
W/m²•K
% of Assembly
Roofs
sm
0
0%
Walls (Facing Ground)
vsm
0
0%
Walls (Facing Air)
vsm
0
0%
Floors Exposed
hsm
0
0%
Doors
vsm
0
0%
Windows
vsm
0
0%
Floors (Heated Slabs)
hsm
0
Interior Floors (Non-exposed)
hsm
Envelope Totals
0%
Window:Wall Ratio
0%
(of walls above grade)
Total Conditioned Volume
Total Conditioned Floor Area
0 hsm
Total Surfaces Facing Ground
0 sm
(below grade surfaces)
Total Surfaces Facing Outdoor Air
0 sm
(below-grade surfaces not calc'd)
Total Cond. Area to Volume Ratio
0
(higher is better)
Surface to Volume Ratio (V/A)
0
(lower is better)
ACH50 Value
0
(lower is better)
Thermal Totals
Building U-Value Avg.
0 (exposed to air)
Heating Degree Days
0
Cooling Degree Days
0
HEDI Estimated
0 kWh/m²/yr
CEDI Estimated
0 kWh/m²/yr
Constant Ventilation Rate
ls
Ventilation * Occupants
0 l/s
Heating Season Ventilation Losses
0 kWh
Ventilation Recovery Efficiency
0 %
Recovered Ventilation Energy
0 kWh
Net Ventilation Losses
0 kWh
TEDI Estimated
0 kWh/m²/yr
(excludes ventilation)
Plug Load Watts per m2
Watts
(refer to ASHRAE or NECB values)
Plug Load Hours of Occupancy per Year
Hours
(refer to ASHRAE or NECB values)
Total Annual Plug Loads
26280 kWh
Plug Loads Estimated
87.60 kWh/m²/yr
TEUI Estimated
0 kWh/m²/yr
estimated TEDI + Plug Loads
Peak Heating Load
0 kW
0 BTU/hr
Peak Cooling Load
0 kW
0 BTU/hr
Max. Heating Load Intensity
0 W/m²
0